PerkinElmer

1.999赔率彩票网

OF

无论您的应用,需求或预算如何,我们都有1.999赔率彩票网解决方案来解决您的检测难题。 我们的多元化产品组合包括液相1.999赔率彩票网仪(LC),液相1.999赔率彩票网/质谱联用仪(LC/MS),气相1.999赔率彩票网仪(GC),气相1.999赔率彩票网/质谱联用仪(GC/MS)和Arnel-GC工程1.999赔率彩票网仪,以及顶空进样器和热脱附样品处理系统。此外,您可以通过以下方式优化实验室:

  • 为GC和LC提供统一、易于使用的软件,为您提供更可靠的实验结果
  • 多种检测选项,包括先进的质谱技术

GC Engineered Solutions (Arnel)

Today’s analytical laboratories need more than high quality, reliable instrumentation and information. They need complete systems and guaranteed solutions that meet industry standards and specifications. We offer nearly 100 turnkey standard analyzers and products that provide Engineered Analytical Solutions.
Clarus 690 GC
Clarus 690 GC

Clarus 590 and 690 GC

  • Better characterization and fewer reruns with wide range flame ionization detector (FID)
  • Lower reporting limits and improved inertness with high performance Capillary Injector
  • Higher throughput with best-in-class, fastest-heat-up and cool down conventional GC oven
  • More versatility with multiple, industry-leading TurboMatrix™ sample handling options
Flexar UHPLC
Flexar UHPLC

Flexar FX-20 UHPLC

  • Up to 10X throughput improvement with solvent delivery at up to 18,000 psi for UHPLC columns
  • Flexibility and sensitivity to apply to conventional or the most complex applications
  • Lower operating costs with more than 90% reduction in solvent consumption
QSight Triple Quad LC-MS
QSight Triple Quad LC-MS

QSight Triple Quad LC/MS/MS

  • Self-cleaning StayClean source with hot-surface induced desolvation (HSID) is designed for maximum sensitivity and enables up to 15% more uptime
  • Laminar Flow Ion Guide for highly efficient field-free transmission
  • Dual Source technology gives you the capability to set ESI or APCI modes, with two independent probes for true multiplexing

开奖大厅

产品与服务 (90)
Filters:

Filters :

产品类型
  • Consumables (39)
  • Instruments (25)
  • Accessories (25)
  • Software and Informatics (1)
长度
  • 51-100 (7)
  • 31-40 (2)
温度-最高
  • 30-40 (24)
  • 20-30 (4)
  • Over 100 (4)
  • 40-50 (1)
温度-最低
  • 10-20 (27)
  • 0-10 (7)
  • 90-100 (1)
产品品牌名称
  • TurboMatrix (20)
  • Clarus (7)
  • Arnel (6)
  • AxION (2)
  • Torion® (1)
产品组
  • Clarus SQ 8S (1)
  • Clarus SQ 8C (1)
  • Barcode Readers (1)
  • Clarus SQ 8T (1)
技术
  • Gas Chromatography (14)
  • Gas Chromatography/Mass Spectrometry (3)
技术类型
  • Chromatography (11)
  • Mass Spectrometry (1)

1-12 的 90 产品与服务

  • PerkinElmer
  • PerkinElmer
  • PerkinElmer
  • Clarus 590

    Clarus 590 气相1.999赔率彩票网

    全新的Clarus® 590气相1.999赔率彩票网引入新技术,从而改进了灵敏度,降低残留效应,使得整个系统易于使用和维护。全新的Clarus 590采用和Clarus 690相同的创新设计,你可选择最通用的样品处理系统。

    另外创新适用性强大的TurboMatrix顶空进样和热解析进样系统可以针对您的具体需求提供多样化的仪器配置。

  • 热脱附-气相1.999赔率彩票网质谱 火灾分析

    火灾调查涉及许多不同类型的分析-从犯罪现场调查,到分析化学检测。
  • Clarus-580-GC_320px

    气相1.999赔率彩票网法测定生物乙醇

    甲醇和高级醇的含量测定是保证生物乙醇产品质量的关键一步。珀金埃尔默根据 ASTM d5501提供此应用解决方案,方案采用Clarus® 680气相1.999赔率彩票网仪(GC),检测快速,结果准确。
  • Flexar UHPLC

    Flexar UHPLC

    在进行较高难度的分析应用时,当您需要在短时间里获得更多的数据,Flexar UHPLC是一个完美的选择。Flexar UHPLC主要用来检测高通量样品,具备高灵敏度和分离度,超乎寻常的流量精准度和快速分析等特点。
  • QSight Triple Quad LC-MS

    QSight Triple Quad LC/MS/MS

    强大可靠的QSight® 三重四极杆液质联用系统是分析食品,大麻和环境样品的理想选择,可始终如一地提供分析测试实验室所需的高通量和高效率,QSight系列发布了旗舰机型:高性能400系列,具有业界所见的最高灵敏度和高通量,并且这种易于实施的解决方案,能够测试最具挑战性的复杂样品,包括大麻。
  • CLARUS-SQ-8_V2_200px

    用于邻苯二甲酸酯检测的气相1.999赔率彩票网/质谱分析系统

    PerkinElmer 以Clarus®SQ8 GC/MS为核心提供一个完整的解决方案,方案稳定且准确的,检测限远远低于法规的要求。
  • AxION 2 TOF MS

    AxION 2 飞行时间质谱

    AxION® 2 TOF MS 提供简化的分析流程,让您能够轻松获得最佳的结果。
  • 顶空-气相 测定生物柴油甲醇

    甲醇的测定对于保证生物柴油的质量至关重要。 珀金埃尔默提供根据 EN 14110标准的解决方案,采用 Clarus®气相1.999赔率彩票网仪联合TurboMatrix™顶空进样器,提供自动化的检测过程和准确可靠的结果。
  • QSight LX50 Solvent Delivery Module

    QSight LX50 溶剂输送模块

    QSight® LX50 超高压液相1.999赔率彩票网与QSight三重四极杆LC/MS/MS及其Simplicity 软件完美结合,可提供从样品处理到数据采集和报告的最高效率。 该系统包括三项关键技术,可帮助优化您的工作流程并实现高效率。
  • Jump to:
Business Insights (36)
Filters:

Filters :

資源庫
  • Application Note (24)
  • Brochure (3)
  • Flyer (2)
  • Product Note (2)
  • Article (2)
  • Case Study (1)
  • FAQ (1)
  • Technical Note (1)

1-12 的 36 Business Insights

  • 产品手册

    TurboMatrix Thermal Desorbers for Gas Chromatography

    For laboratories analyzing everything from air quality to flavors and fragrances, thermal desorption offers a faster, easier, more cost-efficient way to prepare samples for GC or GC/MS analysis. Ideal for the trace-level measurement of volatile organic compounds (VOCs)—as well as most semi-volatile chemicals—thermal desorption lets you avoid time-consuming, manual, solvent-based sample preparation in favor of a simple, streamlined, automated approach. It also delivers the added benefits of superior throughput and enhanced sensitivity.

  • 产品手册

    QSight Pesticides Analyzer Brochure

    Pesticides can adversely affect human health through the food we consume but can also leach into soil and groundwater and impact us through the environment. To keep up with a complex and constantly changing regulatory environment, your pesticide analysis solution needs to keep up with your burgeoning sample load.

  • 产品手册

    Clarus 590 and 690 Brochure

    In today’s budget-constrained, yet highly competitive laboratory environments, the samples you’re being asked to analyze - whether food, pharmaceutical, petrochemical, or environmental - are increasingly difficult. But for some labs, having a dedicated GC for every application isn’t an option. For them, a GC that can do it all isn’t just a nice-to have, it’s a necessity.

  • 产品说明

    Torion T-9 GC MS

    Although it was built for portability and speed, the low thermal mass (LTM) capillary GC provides equivalent chromatographic resolution and performance to a benchtop system. The miniature size is achieved by replacing a conventional convectively-heated column oven with a low thermal mass (LTM) column bundle with direct-contact electrical resistive heating. LTM GC uses a small diameter, metal capillary GC column, which is bundled with resistive heating and temperature-sensing wires that are braided Superior technology • Small diameter LTM capillary GC for high speed, high resolution separation of chemical analytes • Rapid temperature programming delivers analysis times of under three min. • Sensitive and selective mass-based detection of a wide range of chemicals • Easy to operate with a color touch-screen display and simple navigation buttons Figure 1. The Torion T-9 Low Thermal Mass Capillary GC is fast and operates reliably. Injection Port with Removable Liner LTM Capillary Column Bundle Cooling Fan Electronic Pressure Control GC Electronic Board together with insulator strands. This design provides for greater heating and cooling speeds and very low power consumption

  • 产品说明

    Ozone Precursor System

    The analysis of C2 to C12 volatile organic ozone-precursor compounds can present a serious technical challenge to the analytical chemist. Low concentrations in the atmosphere coupled with the need to monitor frequently to assess diurnal variations means that a preconcentration step of the sample before analysis by thermal desorption is required. While the samples can be collected in the field and returned to the laboratory, remote, field-based analysis is desired which allows reduced data turnaround time, minimizes sample collection hardware and permits the presence or absence of VOCs to be correlated with meteorological data. In the field, low-molecular-weight C2 VOCs can be trapped on solid adsorbents if those adsorbents are cryogenically cooled.

  • 应用文献

    Rapid In-Field Screening for Fentanyl Analogs

    In recent years there has been an increase in fatalities related to the use and consumption of opioids, a class of synthetically manufactured pain-relieving drugs similar to naturally derived opiates like morphine, opium, codeine, and heroin. This application demonstrates the use of the novel Custodion® Coiled Microextraction (CME) syringes and the Torion T-9 Portable GC/MS as a fast and easy to use screening tool for drugs of abuse and new psychoactive substances (NPS) in the field.

  • 应用文献

    Improved Sensitivity and Dynamic Range Using the Clarus SQ8 GC/MS System for EPA Method 8270D

    This analysis focuses on the detection of trace level semi-volatile organic compounds in extracts from solid waste matrices, soils, air sampling media and water samples. The method lists over 200 compounds however a majority of laboratories target between 60 and 90 for most analyses. The study presented here demonstrates the PerkinElmer® Clarus® SQ 8 GC/MS, not only meets the method requirements but provides users flexibility to satisfy their individual productivity demands. An extended calibration range is presented as are the advantages of the Clarifi™ detector.

  • 应用文献

    Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17

    Optimized methods are needed for the analysis of toxic compounds in air to understand the impact to human health. People breathe approximately 20,000 liters of air a day so this concern is significant. EPA Method TO-17 is used to determine toxic compounds in air after they have been collected onto sorbent tubes. This application note demonstrates that the PerkinElmer TurboMatrix™ Thermal Desorber and the PerkinElmer Clarus® SQ 8 GC/MS will meet and exceed the criteria set forth in EPA method TO-17. Detailed instrument method parameters are presented, with precision, recovery, linearity and detection limit results.

  • 应用文献

    Determination of 2,4,6-Trichlorophenol in water by Derivatization in headspace and GC/MS

    Chlorophenols are by-products of the drinking water purification process and are also widely used as wood preservatives, herbicides and pesticides. In this study, the derivatization and extraction happened in the headspace vials during the vial thermostatting step. The derivatization reaction is affected by temperature and time, therefore the thermostat time and oven temperature of the headspace sampler were investigated for optimum derivitization/extraction conditions.

  • 应用文献

    Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8

    This method outlines the analysis of volatile organic compounds in a variety of solid waste matrices including various air sampling trapping media, ground and surface water, soils, and sediments among others. The method requires not only demonstration of laboratory sample preparation and handling competence but instrument performance as well. The study presented here demonstrates the PerkinElmer® Clarus® SQ 8 GC/MS with purge and trap sample introduction both meets and exceeds the performance criteria set out in method 8260C and describes the analytical results and instrumental methodology.

  • 应用文献

    Ambient Air Monitoring - U.S. EPA PAMS

    Air pollution is a global concern. Ground-level ozone has become an increasingly important issue in developed nations, as the health effects of smog are more clearly understood. The monitoring of VOC ozone precursor compounds will continue to play a role in defining and reducing air pollution in developed and developing nations in the next decade. The data presented here shows the excellent results of improved separation via Elite-624Sil MS column with real world samples, simplified column connections to the Dean Switching device and trap with modernized triple bed trap with guard zone technologies.

  • 应用文献

    Rapid Identification of Illicit Drug Substances

    This study describes the injection, separation, and identification of 16 drug compounds in less than 10 minutes using portable gas chromatograph-toroidal ion trap mass spectrometry (PerkinElmer, Torion T-9 Portable GC/MS) combined with a coiled-wire-filament (CWF) sampling injector to provide an effective tool for onsite analysis of illicit drugs substances.

  • Jump to: